perm filename BOIL.DAT[D,LES] blob sn#192559 filedate 1975-12-17 generic text, type C, neo UTF8
COMMENT ⊗   VALID 00002 PAGES
C REC  PAGE   DESCRIPTION
C00001 00001
C00002 00002	\|\\⊂'445\⊂'1000001\M0BASL30\M1BASI30\M2BASB30\M0NGR25\
C00006 ENDMK
C⊗;
\|\\⊂'445;\⊂'1000001;\M0BASL30;\M1BASI30;\M2BASB30;\M0NGR25;\;
Stanford Artificial Intelligence Lab\RDecember 17, 1975

\F2\CElectronic Boilerplate

Construction and Utilities

\F0\JThe electronics shall be of solid state circuit components, in
general, and shall be mounted on printed-circuit modular plug-in
units.  All equipment shall be so constructed as to permit
accessibility to any and all component parts for ease of maintenance
and replacement - without disconnecting any external cables.  All
construction shall be of the highest quality according to electronic
industry standards.

The system shall be completely assembled.  Stanford shall in no way
provide any equipment such as, but not limited to, racks; cabinets;
cooling fans; generators; power supplies; etc.  All terminals, plugs,
connectors, circuit wiring, etc., shall be uniquely labeled on the
equipment and referenced to a set of system drawings.  Adequate
interlocks and safety devices shall be installed wherever necessary
to ensure the safety of personnel and equipment.  All such devices
shall comply with published State of California codes.

The operating line voltage for the system shall be taken from
commercially available power, namely 117v single phase at a frequency
of 60 cycles per second +2 or -2 cycles.  The system shall operate
over an input voltage fluctuation of plus or minus 10 percent of
normal.

The system shall operate as specified within a room temperature range
of +55 degrees to +100 degrees F.  Any internal cooling requirements
shall be supplied by the Seller.

The terminals will normally be in use on a 24-hour day, 7-day week basis
and should be so designed as to permit operation in this way.

\F2Maintenance\F0

The Buyer expects to maintain the system himself.  The Seller shall
provide any necessary test equipment for maintenance and adjustment
other than a Tektronix type 547 oscilloscope with type 1A1 plug-in,
type P6020 current probe and type 132 amplifier, and a 20,000 ohm per
volt multimeter.

\F2Documentation\F0

The Seller shall supply one operation manual for each terminal.
The Seller shall also supply three complete maintenance manuals,
including all circuit schematics, logic drawings, and interconnection
drawings as are necessary for maintenance of the units.